      Type:thermocouple (thermal resistance) for power station

      Illustrate:It is specially designed for power station to measure temperature for 30KW, 60KW power-generating set and concerned equipments. It is used to directly measure the temperature of liquid, vapor, gas, and solid surface ranging from-200℃ to 800℃ during production process.

      Thermocouple (Thermal Resistance) for Power Station
       

      Application
      It is specially designed for power station to measure temperature for 30KW, 60KW power-generating set and concerned equipments. It is used to directly measure the temperature  of liquid, vapor, gas, and solid surface ranging from-200℃ to 800℃ during production process.
      Operation Theory
      Thermocouple electrodes are made of two different materials. Temperature difference between measuring end and reference end results in pyroelectric potential, then display meter indicates the corresponding temperature to the pyroelectic potential.
      It is based on that temperature change of material results in change of its resistance. When resistance value changes, the working instrument will display relevant temperature value.
       
      Main Technical Parameters
      Executive Standard
      IEC584
      GB/T16839-1997
      JB/T8622-1997
      JB/T8623-1997
       
      Measuring Range & Tolerance
      Thermocouple
       

      Type Graduation Tolerance Class
      I II
      Tolerance Value Measuring Range °C Tolerance Value Measuring Range °C
      WRN K ±1.5°C -40~+375 ±2.5 °C -40~+333
      ±0.004ltl 375~1000 ±0.0075 ltl 333~1200
      WRE E ±1.5°C -40~+375 ±2.5°C -40~+333
      ±0.004 ltl 375~1000 ±0.0075 ltl 333~900
       
      Thermal Resistance
       

      Type  Graduation Measuring Range ℃ Accuracy  Tolerance
      WZP Pt100 -200~+500 A
      B
      ±(0.15+0.002) ltl
      ±(0.30+0.005) ltl
      WZC Cu50  
      Cu100
      -50~+100 --- ±(0.30+0.005) ltl
       Note: It is absolute temperature value actually tested with thermal sensor.
       
      Insulation Resistance at Normal Temperature
       
      The insulation resistance between electrode and protection tube of thermocouple shall be no less than 1000Ω.m under condition that environment temperature is 20±15℃,relative humidity is no more than 80%, and testing voltage is D.C.500±50V.
       
      The insulation resistance between electrode and protection tube of thermal resistance shall be no less than 100M Ωunder condition that environment temperature is 15~35℃,relative humidity is no more than 80%, and testing voltage is D.C.10~100V.

      Last:Without the Next:wear-resisting thermocouple

      Contact Us

      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

      Phone:021-57635022

      E-mail:info@gnflowmeter.com

      E-mail:sales@gninstruments.com

      關(guān)閉
    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>