      Type:Zirconia Oxygen Analyzer

      Illustrate:CX-ZOA-1404 series of zirconia oxygen analyzer is a kind of practical and reliable on-line automatic oxygen analyzer. Its measurement and display system consists of an oxygen detector (sensor) and a display instrument (transmitter).

      CX-ZOA-1404 Zirconia Oxygen Analyzer
       
      CX-ZOA-1404 series of zirconia oxygen analyzer is a kind of practical and reliable on-line automatic oxygen analyzer. Its measurement and display system consists of an oxygen detector (sensor) and a display instrument (transmitter). The detector is made of heat-resisting and anti-corrosion materials and can be directly inserted into flues for measurement of oxygen. The display instrument adopts single-chip control and can be used in combination with various packaged electronic instruments, ordinary display and recording instruments and distributed control systems (DCS).
      CX-ZOA-1404 series of zirconia oxygen analyzer is used for rapid and accurate on-line measurement and analysis of the oxygen contents in the flue gas produced by combustion equipments, such as boilers, furnaces and heaters, so as to realize control of low-oxygen combustion, energy saving and pollution abatement.
      Features:  
      The senor is made of heat-resisting and anti-corrosion materials with high reliability.
      With a special structural design, this analyzer needs no external air pump, and the reference air can realize
      convection by itself.
      The sensor has a standard air interface, which enables calibration check on the site and provides convenient
      maintenance.
      It adopts single-chip control and data processing with quick response, accurate measurement and stable
      performance.
       
      Technical indexes:

      Measuring range: 0~20.6%02
      Accuracy: ≤±2%FS
      Temperature of flue gas measured: ≤800℃
      Excess air coefficient of flue gas measured: 0.1-99
      Response time: ≤3 seconds (90% response)
      Current output: 0-10mADC or 4-20mADC
      Power supply: 220V±10% 50HZ± 5%
      Working conditions: ambient temperature: 0~50℃
      Relative humidity <85%
      Heating-up time of the heater of zirconia detector: Approx. 20 minutes
       
      Overall dimensions and opening size
      Type Overall dimension mm Dimension of the hole mm (height * width)
      Horizontal (H) 160*80*260 152*76
      Vertical (Z) 80*160*260 786*152
      Square (Q) 160*160*260 152*152
      Wall mounting (G) 220*170*75 (height * width* thickness)
       

      Last:Silicate Analyzer Next:沒有了

      Contact Us

      Office Address: Rm612-613.Jiahe Sunnyplaza.No.76.Jiuxin road.Jiuting Town,shanghai,china

      Phone:021-57632436

      E-mail:info@gnflowmeter.com

    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>