      Type:CX-IAC-1501 industrial acid concentration meter

      Illustrate:It’s widely used for continuous monitoring of residual chlorine and PH values of a variety of water quality in electric power plants, water plants, hospitals and other industries

      CX-IAC-1501 On-line Residual Chlorine Analyzer

      Brief Introduction
      1.It is a new residual chlorine analyzer manufactured by our company
      2.CX-IAC-1501 is a high-intelligence on-line monitor, which is composed of the sensor and the secondary instrument.
      3.It can measure residual chlorine, PH and temperature simultaneously. 

      Main Features
      1.Multi-parameter display: On the same screen, residual chlorine, temperature, PH value, output current (HOCL or chlorine electrode input current), status and time are displayed.
      2.History curve: It automatically stores residual chlorine measurement data every 5 minutes and it can continuously tore a months of residual chlorine values. On the same screen, it provides “History Curve” display and “Timed” query.
      3.Notepad: The notepad faithfully records the operation of the instrument and the occurrence time of the alarm, easy for management.
      4.Monitoring electrode: The calibration mode, the time and the result are recorded every time, easy to inquire and analyze the electrode changes.
      5.Clock: It provides different time references.
      6.Excellent display: It adopts 192×64 bitmap format backlit LCD display, achieving graPHics and Chinese display. With the adjustable uniform background light, you can clearly observe and operate the instrument in the dark conditions outdoors.
      7.Stable instrument not crashing: The watchdog process ensures the instrument to work continuously and not to crash.
      8.Manual current source function: You can check and arbitrarily set the output current value, facilitating to detect
      the recorder and the lower computer.
      9.Software set current output mode: Software selection is 0~10mA or 4~ 20mA output, and the user needn’t push
      any switch.

      Main Parameters

      Measuring range  Residual chlorine: 0-20.00mg/L,     Resolution: 0.01mg/L;
      HOCL: 0-10.00mg/L               Resolution: 0.01mg/L;
      PH value: 0 - 14.00PH              Resolution: 0.01PH;
      Temperature: 0- 99.9 °C            Resolution: 0.1 °C
      Accuracy Residual chlorine: ± 2% or ± 0.035mg / L, take the bigger;
      HOCL: ± 2% or ± 0.035mg / L, take the bigger;
      PH value: ± 0.05PH
      Temperature: ± 0.5 °C (0 ~ 60.0 °C)
      Sample temperature 0 ~ 60.0 °C, 0.6MPa
      Sample flow rate 200 to 250 mL/1min  Automatic and Adjustable
      Minimum detection limit 0.01mg / L
      Repeatability error of the electronic units  Residual chlorine: ± 0.02mg/L, PH value: ± 0.02PH
      Stability Residual chlorine: ± 0.02 (mg / L)/24h, PH value: ± 0.02PH/24h
      PH Input Impedance ≥ 1012 Ω
      Clock accuracy  ± 1 min/month
      Isolated current output 0~10mA(load <1.5 kΩ), 4~20 mA(load <750Ω)
      Output current error ≤±1%FS
      Data storage capacity l month (1 point/5 minutes)
      High and low alarm relays AC220V, 7A; Hysteresis Amount 0- 5.00mg / L; Arbitrary Regulation RS485 communication interface (optional)
      Power Supply AC220V ± 22V, 50Hz ± 1Hz; DC24V (optional). If it is not specified when ordering, AC220V is the default power supply
      Protection IP65
      Power: ≤ 10W
      Working Conditions:  ambient temperature: 0 ~ 60 °C;  relative humidity <85%;
      Overall dimension 146 (length) x 146 (width) x 108 (depth) mm; dimension of the hole: 138 x 138mm
      Weight Secondary Instrument: 0.8kg, flow cell with residual chlorine, PH electrode weight: 2.5kg;
      Note: The user can select two-way current input; one way of residual chlorine corresponds to current output, and the other way of optional PH or temperature corresponds to the current output. The ex-factory standard configuration is that one way of residual chlorine corresponds to the current output. Please specify when ordering

      Last:CX-RCA-1503 residual chlorine a.. Next:沒(méi)有了

      Contact Us

      Office Address: Rm612-613.Jiahe Sunnyplaza.No.76.Jiuxin road.Jiuting Town,shanghai,china