      Type:CX-IDO-1303 industrial dissolved oxygen meter

      Illustrate:It can be widely used in such fields as thermal power plants, chemical industry, chemical fertilizer, metallurgy, environmental protection, pharmacy manufacturing, biochemistry, foodstuff and running water.

      CX-IDO-1303 Industrial Dissolved Oxygen Meter


      Brief Introduction
      1.It’s the intelligent on-line chemical analyzers developed by out company.
      2.With strong environmental adaptability, clear display, easy operation and excellent measuring performance
      3.It can measure out the accurate DO value and temperature of a solution

      Main Features
      1.Adopts high-precision AD conversion and single chip microcomputer processing technologies
      2.Used for measurement of the DO value and temperature
      3.automatic temperature compensation and self-checking
      4.High protection grade: It adopts waterproof and dust-proof design and is applicable for outdoor use
      5.Multi-parameter display: The DO value and temperature values can be displayed on the screen at the same time.
      6.It adopts LED display module with high brightness.
      7.It can be easily connected to a computer to perform monitoring and communication.

      Main Parameters

      Measuring range and error 0~100.0 ug/L; 0~20.00 mg/L(automatic switching); 0~60C
      Resolution 0.1 ug/L; 0.01 mg/L; 0.1C
      Intrinsic error of the whole instrument ug/L: ±l.0%FS; mg/L: ±0.5%FS, temperature: ±0.5C
      Repeatability ±0.5%FS
      Stability ±1.0%FS
      Automatic temperature compensation range  0~60C, with 25C as the reference temperature
      Response time <60s (98% and 25C of the final value) 37C ,98% of the final value < 20 s
      Output current error ≤±l.0%FS
      Isolated output 4~20 mA(load resistance <750Ω)
      Communication interface RS485 or 232(optional)
      Data storage capacity l month (1 point/5 minutes)
      Time of saving data 10 years
      Alarm relay AC 220V, 3A
      Power supply 220V±10% 50±1HZ
      Overall dimension Secondary meter: 146 (length) x 146 (width) x 108 (depth) mm;
      Dimension of the hole: 138 x 138mm
      Working conditions ambient temperature: 0-60C; relative humidity <85%
      The connection tubes for inlet and outlet water Φ8, Φ10 and Φl2.

      Last:CX-IDO-1304 industrial dissolve.. Next:CX-IDO-1301 industrial dissolve..

      Contact Us

      Office Address: Rm612-613.Jiahe Sunnyplaza.No.76.Jiuxin road.Jiuting Town,shanghai,china

      Phone:021-57632436

      E-mail:info@gnflowmeter.com

    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>