      Type: CX-PR-ASR100 color paperless recorder

      Illustrate:This manual helps customers to realize the function, setting, connection methods and ways of disposal when you meet problem. We earnestly request you to read this manual carefully before using in order to avoid damaging instrument and injuring person.

      CX-PR-ASR100 Color Paperless Recorder


      Attention
      1.There are many plastic parts in this instrument panel. Please do use dry soft cloth for cleaning.
      2.Solvents are not allowed for cleaning.
      3.Please keep the LCD screen away from any sharpen goods.
      4.Please keep any mechanical impact away during the instrument working. It might cause internal component dam age or
      5.system breaks down. Turn offthe power for any maintenance if necessary. P lease contact our customer service department or
      6.local dealer ifany unusual sound, belches smoke or unusual smell was found.
      7.Turn off the power when the instrument is maintained.
      8.Not insert or pluck the lines of communication.
       
      Environment
      1.To ensure the instruments be normal working, non-strong interference control panel is strongly recommended to be installed on.
      2.The panel steel plate thickness should not be lower than 4mm.
      3.The instruments operating ambient temperature: -15 - 60 , humidity: 10% - 85% (without condensation) is recommended.
      4.Please keep away from the direct sunlight, the multi-steam, the multi-caustic gases and the source ofthe electromagnetism environment.

      Main Parameters

      Accuracy 0.5 %FS±1 digit  or  0.2%FS±1 digit
      Small-signal removal 0 — 25.5%FS
      Measuring range -9999 — 99999 digit
      Sampling Period 0.25 second
      InterrecordTime Between 1 second and 4 minutes take a second as a unit there are 240 ways for you to choose
      Display mode High resolution, brightness adjustable, wide view angle and bright TFT color LCD (320x234)                     with saving screen (5.6” for ASR100 series)
      Parameters setting ByKey nods or upper linking computer setting. Security lock function is available
      Alarm 4alarmpointsperchannelareavailable.Upper/loweralarm, rate-of-change and differential limit; Alarm output delay, alarm  delay  high  to  low,  external connection  sound available, max 12 latest alarm  messages  are  saved  per channel.
      Communication port RS-232,RS-485:Buadrate1200–115200bps
      Printer       TPμP-A40 micro printer is recommended.
       
      Capacity(Mbit) Interrecord time (S) Channel  Number Approx recording date
      32 (Default configuration)
       
      10 1 683
      2 341
      4 170
      8 82
      12 55
      240 1 16401
      2 8200
      4 4100
      8 1984
      12 1322
      64(Extened)
       
      10 1 1594
      2 797
      4 398
      8 192
      12 128
      240 1 38037
      2 19134
      4 9567
      8 4629
      12 3086
      128(Extend)
       
      10 1 3415
      2 1705
      4 850
      8 410
      16 275
      240 1 82005
      2 41000
      4 20500
      8 9920
      12 6610

      Last:Without the Next:CX-PR-ASR200 paperless recorder

      Contact Us

      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

      Phone:021-57635022

      E-mail:info@gnflowmeter.com

      E-mail:sales@gninstruments.com

      關(guān)閉
    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>