      sales@gninstruments.com

      Type:CX-FT-LK80 flow totalizer

      Illustrate:with auto-compensation and accumulating calculation is applicable in the measurements for various liquids, vapors,natural gas and ordinary gases. It has been widely used for flow-controlling with accumulating calculation in the fields of biology, oil, chemical engineering, metallurgy, electric power, pharmacy, food engineering, energy managing, mechanical engineering, aviation and astronautics

      CX-FT-LK80 Flow Totalizer


      Main Features
      1.Auto T & P compensation
      2.High precision table T & P compensation
      3.Auto calculating Flow coefficient K
      4.MC based auto digital regulating
      5.Open to set all internal parameters
      6.Select various input signals
      7.Convenient to net communicating
      8.LED / LCD display available
       
      Communication Type

      Selection code 0 2 3 4 8 9
      Communication No RS-232 Print interface RS-422 RS-485 Special type
       
      Control output type

      Selection code  0 1 2 3 4 5 6 7 8 9
      Output No Relay 4~20mA 0~10
      mA
      1~5V 0~5V SCR output SSR output Special type SOT output
       
      Variable Output Type

      Selection code 0 2 3 4 5 8
      Output Without output 4~20mA 0~10mA 1~5V 0~5V Special type
       
      Input Type(default)

      Selection Code Input Range Code Input Range Specification
      A 4~20mA -1999~99999 d G Pt100 -200~650C All the listed are the max.range . And  in this range ,user can modify the secondary parameters to confirm the range .
      B 0~10mA -1999~99999 d E RTD E type 0~1000C
      C 1~5V -1999~99999 d K RTD K type 0~1300C
      D 0~5V -1999~99999 d R Customize -1999~99999 d
      M 0~20mA -1999~99999 d N No compensation input  
      F pulse 0~5KHz      
       

      Last:Without the Next:Without the

      Contact Us

      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

      Phone:021-57635022

      E-mail:info@gnflowmeter.com

      E-mail:sales@gninstruments.com

      關(guān)閉
    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>