      Type:CX-IAC-1401 industrial acid concentration meter

      Illustrate: CX-IAC-1401 Industrial Acid Concentration Meter Brief Introduction 1.Characters: intelligence, multiple functions, high measuring performance, and strong environment adaptability. 2.It can be used to test the concentration of the regenerated li..

      CX-IAC-1401 Industrial Acid Concentration Meter


      Brief Introduction
      1.Characters: intelligence, multiple functions, high measuring performance, and strong environment adaptability.
      2.It can be used to test the concentration of the regenerated liquid in high-purity water preparation process by means of ion exchange.
      It can also be used for continuously monitoring the concentration of the hydrochloric acid in the pickling solutions for clean boilers and pipelines.

      Main Features
      1.Intelligent: adopts high-precision AD conversion andsingle chip microcomputer processing technologies.
      2.It can be used for the measurement of the HCLconcentration and temperature, automatic temperature compensation, automatic range switching andself-checking.
      3.Reliability: All the components are arranged on one circuit board. No complicated functional switch, adjusting knob or potentiometer is arranged on this instrument.
      4.Strong interference immunity: Its current output adopts optoelectronic isolating technology.
      5.This meter has strong interference immunity and the capacity of long-distance transmission as well as excellent electromagnetic compatibility.
      6.Waterproof and dust-proof design: Its protection grade is IP65. It is applicable for outdoor use.
      7.Automatic range switching: The measuring ranges can automatically switch within the measuring range of the
      electrode.
      8.Communication interface: It can be easily connected to a computer to perform monitoring and communication.
      Phase sensitive detection: Eliminating the influence of conductors on the measurement of hydrochloric acid
      concentration.
      9.Automatic measuring frequency switching: This can help prevent electrodes from polarization, so as to enhance
      their accuracy.

      Main Parameters

      Measuring range and error (0~10)% HCL; (0~30)% HCL; temperature: 0~99.9°C
      Intrinsic error of electronic units concentration: ±1.0%; temperature: ±0.3°C
      Intrinsic error of the instrument concentration: ±2.0%
      (the error can less than 0.05% after usual point calibration.)
      Repeatability ±1.0%
      Stability ±1.0%/24h
      Automatic temperature compensation range 0~99.9°C
      Solution tested 0~99.9°C, 0.6MPa
      Output current error ≤±1%FS
      Communication interface RS485 or 232(optional)
      Protection IP65
      Isolated current output 4~20 mA(load <750Ω)
      Compensation range of the temperature coefficient (0-10.0)% /°C (adjustable)
      Alarm relay AC 220V, 3A
      Data storage capacity One month (1 point/5 minutes)
      Saving time of data
      under a continuous power-failure condition
      10 years
      Power supply AC220V±22V, 50Hz±1HZ
      Overall dimension of the instrument 146 (length) x 146 (width) x 108 (depth) mm
      Dimension of the hole 138 x 138mm
      Working conditions ambient temperature: 0-60°C; relative humidity <85%
      Clock accuracy ±1 minute/month

      Last:CX-IAC-1401A industrial acid / .. Next:Without the

      Contact Us

      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

      Phone:021-57635022

      E-mail:info@gnflowmeter.com

      E-mail:sales@gninstruments.com

      關(guān)閉
    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>