      Moist Air Insertion Thermal Flow Meter

      Email: sales01@cxflowmeter.com
      WhatsApp: +0086 180 4984 1995

      Moist Air Insertion Thermal Flow Meter
       
      I. Customer Needs and Technical Solution Matching Analysis
       
      1. Core Needs Review
       
      Requirement Item: Customer's explicit requirements
       
      Media: Moist air (containing 36g/Nm³ of water), with trace dust
       
      Operating Parameters: Temperature 90℃, Pressure 40mmwg (approximately 0.004MPa), Flow range 80,000-120,000 KG/h
       
      Installation and Maintenance: Insertion flange connection (DN1400 pipeline), supports online CIP cleaning, detachable measuring body
       
      Functional Requirements: Temperature and pressure compensated output mass flow rate, 4-20mA signal, on-site zero-point adjustment
       
      2. Technical Personnel Recommended Solution (Vortex Flow Meter)
       
      Recommended Model: CX-VFM-GB-1400-G-4/R4-D-D-I
       
      II. Adaptability Analysis of Insertion Thermal Gas Flow Meter
       
      1. Technical Advantages of Thermal Flow Meter
       
      Direct Mass Flow Measurement: No external temperature and pressure compensation required; directly outputs mass flow rate through thermal diffusion principle, reducing error propagation.
       
      High accuracy and wide range: Typical accuracy ±1%, range ratio up to 100:1, suitable for scenarios with large flow fluctuations.
       
      Moisture and dust resistant design: The moisture-proof sensor can withstand humid gases with a moisture content of 50g/Nm³ or higher.
       
      Optional self-cleaning function (such as a backflushing device) or wear-resistant coating to reduce the impact of dust.
       
      Fast response and stability: Sensitive to flow rate changes, suitable for transient conditions, and offers superior long-term stability compared to vortex shear systems.
       
      2. Customized Solutions for Customer Needs
       
      Recommended Model Parameters:
       
      Parameters: Optimized Solution for Insertion Thermal Flow Meter
       
      Media Compatibility: Humid air (water content ≤50g/Nm³), dust-resistant coating sensor
       
      Flow Range: 50,000-150,000 KG/h (customizable range)
       
      Temperature/Pressure: -40℃~+350℃/≤4MPa (covering 90℃/0.004MPa operating conditions)
       
      Accuracy and Output: ±0.5%~±1% accuracy, 4-20mA+HART protocol (supports remote zero-point calibration)
       
      Maintenance Functions: Online backflushing cleaning, IP67 protection rating, quick-disassembly structure
       
      Materials and Certifications: 316L stainless steel (corrosion resistant), compliant with ISO 9001 quality system
       
      Key Improvements:
       
      Accuracy Improvement: Optimized from 2.5% to ±1%, meeting the needs of fine chemicals or energy management.
       
      Simplified Maintenance: Backflushing device reduces the frequency of manual disassembly, and CIP compatibility is enhanced.
       
      Data Reliability: HART protocol supports remote diagnostics, reducing on-site operational risks. III. Risk Warning and Countermeasures
       
      1. Potential Risks
       
      Dust Blockage: Trace amounts of dust may accumulate on the sensor surface, affecting measurement accuracy over time.
       
      Humid Gas Condensation: High-temperature, humid air may condense on low-temperature components (such as sensor probes), leading to short circuits or corrosion.
       
      Installation Flow Field Interference: For DN1400 large-diameter pipes, ensure insertion depth and flow field uniformity to avoid eddy current errors.
       
      2. Countermeasures
       
      Dust Management: Regularly (every 3-6 months) activate the backflushing device to remove dust.
       
      Select sensors with anti-adhesion coatings (such as PTFE).
       
      Anti-Condensation Design: Install a constant-temperature heating device on the sensor probe to prevent condensation.
       
      Select IP67 protection rating to prevent moisture intrusion into electronic components.
       
      Installation Optimization: Recommended insertion depth is 1/3 of the pipe diameter (approximately 460mm), ensuring the measurement point is located in the mainstream area.
       
      Upstream and Downstream Straight Pipe Section Requirements: Upstream ≥ 5D, Downstream ≥ 3D (D is the pipe diameter).
       
      IV. Final Recommendations and Action Steps
       
      Preferred Recommendation: Insertion-type thermal gas flow meter. Provide a report of measured data under humid gas conditions (e.g., accuracy curve for a water content of 36 g/Nm³).
       
      Demonstrate the backflushing cleaning function and confirm CIP system compatibility.
       
      If the customer insists on a vortex flow meter solution, the following measures are required:
      Add an external temperature and pressure compensation module and clarify the accuracy of the compensation algorithm (recommended ≤0.5%).
       
      Sign a regular maintenance contract, disassembling, cleaning, and calibrating the sensor quarterly.
       
      Contact: CIXIFM Winny
      Email: sales01@cxflowmeter.com
      WhatsApp: +0086 180 4984 1995




       

      Last:沒(méi)有了 Next:Melamine Gear Metering Pump Sel..

      Contact Us

      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

      Phone:021-57635022

      E-mail:info@gnflowmeter.com

      E-mail:sales@gninstruments.com

      關(guān)閉
    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>