• <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
    <center id="o6sq2"></center>
  • <th id="o6sq2"><nav id="o6sq2"></nav></th>
  • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
      <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>

      sales@gninstruments.com

      Location -> Products -> Level -> Level Switch

      Type:high voltage and anti-explosion float level controller

      Illustrate:Control range:25-550mm Flange type:DN80,Outer diameter 200mm Medium temperature:≤150℃ Working pressure:≤4.0MPa Contact capacity: AC 220V 220VA,DC 24~100V 150VA Suitable for the level controller and alarm of the flammable place

      High voltage and anti-explosion float level controller

      Main parameter:
      Control range:25-550mm
      Flange type:DN80,Outer diameter 200mm
      Medium temperature:≤150℃ 
      Working pressure:≤4.0MPa
      Contact capacity: AC 220V 220VA,DC 24~100V 150VA
      Suitable for the level controller and alarm of the flammable place
       
      Main parameters :

      Type Anti-explosion 
      class
      Medium 
      pressure
      Medium 
      temperature
       (℃)
      Switch
       difference 
      (mm)
      Tuning 
      method
      Installation 
      type
      Power and
      contact capacity
      and working life
      CX-FLM-BUQK-01 dIIBT4 4.0 MPa Normal:≤150℃
      High-temp:≤350℃
      ≤14 Not adjustable Horizontal AC:220V,1.5A,
      110V,2.5A 
      DC:24V,2.5A,
      240V,0.5A 
      Working life:
      5×102
      CX-FLM-BUQK-02 dIIBT4 4.0 MPa 25~550 Class adjustable Horizontal
      CX-FLM-BUQK-03 dIIBT4 4.0 MPa 8~1000 No-class adjustable Vertical
       
      2. Structure principle
      Float level controller is consist of float assembly, range switch block and housing.
      A pair of magnetic steel installs at float end and range switch block separately.
      When the float change up and down with the change of level in the limit of movement,
      the magnetic steel will move up and down accordingly. Push the magnetic steel of range
      switch block move via non-magnetic housing. To make the output contact connects of off.
      Control backward signal device send out light or sound signal. When level go up and down,
      only when it within up and low limit of movement, output contact can connect or off, and there
      are no signal send out.
       
      The float of controller and flange is made of SS304, common junction box is SS304, for explosion proof
      type, the junction box is aluminium. The float assembly of controller and range switch block are isolated,
      to avoid leakage and other defect.

       
       

      Last:cable float level switch Next:anti-explosion float level cont..

      Contact Us

      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

      Phone:021-57635022

      E-mail:info@gnflowmeter.com

      E-mail:sales@gninstruments.com

      關閉
    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>