      Type:D541/7T、D541/7TK temperature switch

      Illustrate:D541/7T、D541/7TK Temperature Switch Capillary type thermal element For.neutral gaseous and liquid fluids Working temperature range -30...+280℃

      D541/7T、D541/7TK  Temperature Switch 
       

      Capillary type thermal element                                
      For.neutral gaseous and liquid fluids
      Working temperature range -30...+280℃

      Main Technical Data
        
        Environmentall Temperature:  -25-60℃                                             2    3
          Switching  Element:  micro-switch.
          Housing Protection Garde:  IP65
         (according with DIN40050, and corresponding to IP65 in GB4208)        
          Capillary:  4m                                                                    1
      Terminals 1-3:Contacts ctose on rising temperature
          Materials (Sensor):  Cu
          Vibretion resistence: D541/7T:   40M/s
                           D541/7TS:  20M/s 
          Repeatability Error:  ≤3%
          Contact Capacity: AC220V  6A (resistivity).
          (As for special requirements, you may refer to the Application 
           Manual Written by this factory)
       
       
        □Characterisitic Data

      Adjustable
        Range
       
       
      [℃](°F)
      Switching temperature difference Maximum
      Allowable
      Temperature
       
      [℃] (°F)
      Weight
       
       
       
      [KG]
      Dimensional
      Drawing
      NO.
      Cat. NO.
      Lower
      Range
      [℃] (°F)
      Upper
      Range
      [℃] (°F)
      Switching temperature difference not adjustable (D541/7T)
      -30...+40(-22...104) 4
      (7.2)
      2
      (3.6)
      + 70
      (158)
      0.95  
       
      01
      0891500
      +10...+75
      (50...167)
      5
      (9)
      2.5
      (4.5)
      + 95
      (203)
      0.95 0891700
      +60...+165
      (140...329)
      12
      (21.6)
      4
      (7.2)
      +190
      (383)
      0.95 0891800
      +160...+280
      (+320...+536)
      14
      (35.2)
      6
      (12.8)
      +320
      (608)
      0.95 0891900
      Switching temperature difference adjustable  (D541/7T)
      -30...+40(-22...104) 8...20
      (14.4...36)
      6.5...8
      (11.7...14.4)
      + 70
      (158)
      1.00  
       
      01
      0890500
      +10...+75
      (50...167)
      9...25
      (16.2...44)
      4...10
      (7.2...18)
      + 95
      (203)
      1.00 0890700
      +60...+165
      (140...329)
      18...30
      (32.4...54)
      6...10
      (12.8...18)
      +190
      (383)
      1.00 0890800
      +160...+280
      (+320...+536)
      20...40
      (36..72)
      8...15
      (14.4...27)
      +320
      (608)
      1.00 0890900
      Switching temperature difference not adjustable (D541/7TK)
      -30...+40(-22...104) 2.5
      (6.5)
      1.5
      (2.7)
      + 70
      (158)
      0.95  
       
      01
      0891507
      +10...+75
      (50...167)
      3
      (5.4)
      2
      (3.6)
      + 95
      (203)
      0.95 0891707
      +60...+165
      (140...329)
      6
      (12.8)
      3
      (5.4)
      +190
      (383)
      0.95 0891807
      +160...+280
      (+320...+536)
      7
      (12.6)
      4
      (7.2)
      +320
      (608)
      0.95 0891907

      Dimensional drawing
      01
       
       
       
       
      Accessories
      The selectable accessory catalogue numbers :  0574757.  0574758,
      0574755,  0574772,  0574759,  0574760

      Open protection sleeve R1/2
      For sensor ,cartidge
      Material brass Cat. NO. 0574757
      Material st. St.1.4571
      Cat.NO. 0574759
      Closed protection sleeve R1/2
      For sensor cartridge
      Material brass Cat. NO. 0574758
      Material st. St.1.4571
      (with brass plug) Cat. NO. 0574760
      Removable screw coupling R1/2,
      Material brass,with seal
      (without protection sleeve,
      Up to max.6 bar)
      Cat.ON. 0574755
      7 T-support
      (2 brackets, 4 screws)
      Cat. NO, 0574772


       

      Switch selection and mounting

      instructions
      The switching points should normally be in about
      The middle of the adjustable range.
      Observe switching temperature range, do not subject
      Switch to max. Allowable temperature during normal
      Operation.
      Do not exceed electrical ratings.
      Electrcal connection by a M18*1.5 cable gland, in
      Accordance with local regulations For outdoor
      Installation sufficient are: dractic changes in
      Temperature, solar radiation, penetration of water.
      Setting of the switching points
      Use range spindle to set the upper or lower switching
      Point on designs with fixed switching temperature
      Difference, the opposite one is determined by the
      Fixed switching temperature difference
      On designs with adjustable switching temperature.
      Difference, use range spindle to set the lower
      Switching point, then use differential spindle to set
      The upper switching point by adding the desired
      Switching temperature difference
       
      Turning the range spindle anticockwise shifts both
      Switching points upwards, Turning the differential
      Spindle anticlockwise shifts only the upper switching
      Point upwards,i.e.the switching pressure difference
      (distance between the upper and lower switching
      Points) increases.
      Example:
      Desired: Lower switching point 40℃
             Upper switching point 55℃
             (Switching temperature difference=15K)
      Setting: 40℃(with range spindle)
             15K(with differential spindle)
       
      To set precise switching points a thermometer is
      Reguired.(The temperatue switch is a switching andRegulating device and not a measuring instrument
      - even if it has a scale to assist in the setting).
      The setting can be changed at anytimen, even during
      operation.
       
       
      Making and or breaking capacity Change-over switch with silver sping contacts
      Type 
      of current
       
       Type of  load
      Voltage[V]
      24 60 110 220
      Make and break current[A]
      AC Resistive load
      Inductive load
      Cos≈0.7
      Resistive load.
      Inductive load.
      L/R≈10ms
      Inductive load
      Spark quenching
      With diode
       
      15 15 15 15
      AD 4 2.5 1.5 0.9
      DC 2 0.9 0.45 0.2
      DC 1 0.3 0.09 0.02
      DC 1.5 0.7 0.35 0.15
       
      Spark quenching (direct current):
      Diode in parallel with inductance. Make sure polarity.
      Is correct when making connections.
      Dimensioning of quenching diode (rectifier):
      Rated voltage of diode VD≥1.4XVterm.
      Rated current of diode 1Rated≥1Load
      In case of vigorous contact chatter, use a selenium
      Rectifier if breaking inductance is >2H(rectifiers
      Having a diffusion barrier layer may get distroyed by
      The constant pole reversal).

      Last:CX-TS-ST20 mechanical temperatu.. Next:Without the

      Contact Us

      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

      Phone:021-57635022

      E-mail:info@gnflowmeter.com

      E-mail:sales@gninstruments.com

      關(guān)閉
    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>