      Location -> Electrode pen

      Type:Precision Conductivity,TDS,Salinity Meter

      Illustrate:*Meter factory reset function: users can use this function to reset the meter to the factory default and data log for convenient operation

      Precision Conductivity/TDS/Salinity Meter
      Main Features
      *Microprocessor-based meter, high accuracy, good repetition
      *Self-diagnostic for easy trouble-shooting
      *Meter factory reset function: users can use this function to reset the meter to the factory default and data log for convenient operation
      *3 set buffer selection–NIST, USA, DIN
      *1-3 points automatic push-button calibration
      *Electrode slope display for easy judgment of electrode performance
      *Selectable automatic/manual temperature compensation
      *Stability and average function for optimized results
      *Auto-sleep function for Benchtop meter
      *Auto-off conserves energy and lengthens battery lifespan
      (Portable Meter)
      *Low battery indicator: when battery icon lights up, battery power is low. Replace batteries with fresh ones as soon as possible.
      *Store and output data function: the meter can store up to 500 sets data. Data can be sent to computer via USB link.

      Model Description  Configuration Application Field
      CX-RCB
      6000-01
      Precision Benchtop 
      COND/TDS Meter
      benchtop COND/TDS meter (RCB6000)
      swing arm electrode stand (H-200)
      glass conductivity 
      electrode with ATC (0301W)
      Measuring Cond / TDS for
      surface water, or regular
      simple water, not pure water
      CX-RCB
      6000-02
      Precision Benchtop
      COND/TDS
      For Pure Water
      benchtop COND/TDS meter (RCB6000)
      swing arm electrode stand (H-200)
      glass conductivity 
      electrode with ATC (0302W)
      Measuring Cond / TDS for pure
      water, such as medical, electricity 
      or chemical industries
      CX-RCB
      6000-03
      Precision Benchtop
      Salinity Meter
      benchtop Salinity meter (RCB6000)
      swing arm electrode stand (H-200)
      glass conductivity electrode (0303)
      stainless temperature electrode (T-10)
      Measuring salinity for solution
      CX-RCB
      6000-10
      Precision Benchtop
      COND/TDS/Salinity
      Meter
      benchtop COND/TDS/Salinity meter (RCB6000)
      swing arm electrode stand (H-200)
      glass conductivity electrode (0300)
      glass conductivity electrode (0303)
      stainless temperature electrode (T-10)
      Measuring Cond / TDS / Salinity for
      surface water, or regular
      simple water, not pure water
      Models and Specifications
      Model CX-RCB6000/CX-RCB600
      Cond Range 0-19.99μS/cm / 20.00-199.9μS/cm / 200.0-1999μS/cm /
       2.00-19.99mS/cm / 20.00-199.9mS/cm
      Cond Accuracy 1% FS
      Cond Calibration Point 3 points
      TDS Range 0.000-9.999mg/l / 10.00-99.99mg/l / 100.0-999.9mg/l / 1000-9999mg/l
      Salinity Range 0.0-80.0ppt
      Salinity Solution 0.1ppt
      Temperature Range 0.0-99.9C / 32-212F
      Temperature Solution 0.1C/0.1F
      Temperature Accuracy +/-0.5C/+/-0.9F
      Temperature Compensation 0.0-60.0 C Auto/Manual
      Temperature Coefficient 0.0-3.0% 
      Cell constant 0.1,1.0,10
      Memory 500sets
      Ambient Temperature 5-45C
      Display Meter sleeps (Benchtop) or shuts off (Portable) automatically 
      15 minutes after last key is pressed
      input BNC,φ3.5mm sockets
      output USB
      power 9V DC adepter,500 mA 100/240V (Bench top)
      4X1.5V“AAA”alkaline battery (Portable )
       
      Portable Conductivity/TDS/Saliniity Meter Selection Guide
       
      Model Description  Configuration Application Field
      CX-RCB
      600-01
      Precision Portable 
      COND/TDS Meter
      portable COND/TDS meter (RCB600)
      glass conductivity
       electrode with ATC (DJS-1W)
      Measuring Cond / TDS for
      surface water, or regular
      simple water, not pure water
      CX-RCB
      600-02
      Precision Portable 
      COND/TDS
      For Pure Water
      portable COND/TDS meter (RCB600)
      glass conductivity
       electrode with ATC (0302W)
      Measuring Cond / TDS for pure
      water, such as medical, electricity or
      chemical industries
      CX-RCB
      600-03
      Precision Portable
       Salinity Meter
      portable Salinity meter (RCB600)
      glass conductivity electrode (0303 )
      stainless temperature electrode (T-10)
      Measuring salinity for solution
      CX-RCB
      600-10
      Precision Portable 
      COND/TDS/Salinity
      Meter
      portable COND/TDS/Salinity meter (RCB600)
      glass conductivity electrode (DJS-1)
      glass conductivity electrode (0303)
      stainless temperature electrode (T-10)
      Measuring Cond / TDS / Salinity
      for surface water, or regular
      simple water, not pure water

      Last:Precision Dissolved Oxygen Meter Next:Online pH,ORP Controller

      Contact Us

      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

      Phone:021-57635022

      E-mail:info@gnflowmeter.com