      Type:Laboratory PH Meter

      Illustrate: CX-LPH-1608 Laboratory PH Meter Features: CX-LPH-1608 PH Meter is a digital display PH meter, which adopts the blue backlight, double-row LCD digital display; it can simultaneously display PH and temperature values or potential (mV) and tem..

      CX-LPH-1608 Laboratory PH Meter
       
      Features:  
      CX-LPH-1608 PH Meter is a digital display PH meter, which adopts the blue backlight, double-row LCD digital 
      display; it can simultaneously display PH and temperature values or potential (mV) and temperature values. The
       
      instrument applies to the laboratories in tertiary institutions, research institutes, environmental monitoring,
      industrial and mining enterprises and other departments to measure its PH and potential (mV) values of the
       
      sampled aqueous solution; equipped with ORP electrode, it can measure ORP (oxidation- reduction potential)
      value of the solution; equipped with ion specific electrode, it can measure the potential value of the electrode.
       
       
      Technical indexes:
      1. Instrument level: 0.01
      2. Measuring range: pH: (0.00- 1 4 00) pH
       
      mV: (0 - ± l800) mV (1 auto-display)
      3. Minimum display unit: 0.01 pH, I mV, 0.1 ℃
       
      4. Temperature compensation range: (0.0~60.0)℃
      5. Intrinsic error of electronic units: pH: ±0.01 pH
       
      mV: ±0.1%FS
      6. Intrinsic error of the instrument: ± 0.02 pH ± 1 unit
       
      7. Electronic unit input current: No more than 2 x 10-12A
      8. Electronic unit input impedance: No less than l x l012Ω
       
      9. Error in temperature Compensation: ± 0.01 pH
       
      10. Repeatability error of the electronic units: PH: 0.01 pH ± 1 unit; mV: 1mV ± 1 unit
       
       
      Standard configuration:
      One secondary instrument; one power supply; one 2-in-1 electrode, one temperature electrode; a set of electrode
      support, a set of standard buffer solution
      Ordering guide: To inform the measured medium to facilitate the selection of electrode.

      Last:Laboratory Sodium Meter Next:Laboratory PH Meter

      Contact Us

      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

      Phone:021-57635022

      E-mail:info@gnflowmeter.com

      關(guān)閉
    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>