      Type:Laboratory Bench type pH/ORP mete

      Illustrate:LaboratoryBenchtypepH/ORPmeter CX-PHS-3CtypelaboratorypHmeter Bluebacklight,doubledigitaldisplay Candisplaytemperaturevalue,pHvalueorpotentialvalueofmVatthesametime. Automatic/manualpHtemperaturecompensation,judgepHtemperaturecompensationstat..

      Laboratory Bench type pH/ORP meter
       
      CX-PHS-3C type laboratory pH meter
      • Blue backlight, double digital display
      • Can display temperature value, pH value or potential value of mV at the same time.
      • Automatic/manual pH temperature compensation, judge pH temperature compensation state automatically.
      • Suitable for the PT1000NTC 30kΩ temperature compensation.
      Determination electrode performance automatically, improve the work efficiency.
      Parameter:
      Instrument Class:        0.01class
      Measuring rang:         pH  0.00~14.00pH;                      mV  0~±1800mVResolution:            0.01pH, 1mV, 0.1℃Temp. compensation range: 0~60℃;
      Basic error::           pH±0.01pH;                      mV±0.1%(FS)Instrument basic error:   ±0.02pH±1 character;input current           less than2*10-12Ainput resistance:        less than 1*10 12ΩElectronic unit repeatability error: pH  0.01pH±1 character     mV  1mV±1character
      Instrument repeatability error: less than 0.01pH±1 character
      Electronic unit stability:±0.01pH±1character/3h Overall dimension:  200*210*70mm(L*W*H) Wright:           1kg
      Normal working condition: Ambient temperature:  5~50℃Relative humidity:       ≤85%Power supply:       AC220V±10%  50Hzno significant vibration 
      no other magnetic field interference except the earth's magnetic field 
      Application:
      The instrument is suitable for universities and colleges, research institutes, environmental monitoring, industrial and mining enterprises and other departments of the laboratory sampling determination of the pH of the aqueous solution, and potential value (mV), with ORP electrode can also measure ORP oxidation - reduction potential of solution, mV values.

      Last:Without the Next:Laboratory Sodium Meter

      Contact Us

      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

      Phone:021-57635022

      E-mail:info@gnflowmeter.com

      關(guān)閉
    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>