      Location -> Products -> Flow -> Flowmeter For Gas

      Type:CX-GRFM-LLQ gas roots flowmeter

      Illustrate:CX-GRFM-LLQ gas roots flowmeter can be used to measure air , natural gas ,biogas gas.

      CX-GRFM-LLQ  Gas Roots Flowmeter


      Working Principle
      CX-GRFM-LLQ series gas roots flowmeter is mainly composed of components such as shell,conjugate rotor and counting device etc. A pair of conjugate rotors installed inside the measuring room kept at the correct relative position through precision-machined adjusting gear under the action of pressure difference (Pinlet>Poutlet) between outlet and inlet of circulating air. Continuous noncontact seal is realized by the best working clearance between rotors, rotor and shell, rotor and wallboard. Each time the rotor rotates, it will output gas four times of
      the effective volume of measuring room. The revolution of rotor is transmitted to integrating indicator counter through magnetic seal coupling device and reduction mechanism, thus indicating the accumulative volume of gas outputted. The measuring process and working principle are shown in Figure 1 (only a quarter of one cycle is shown).
       
      Position 1             Position 2             Position 3              Position 4

      Main Technical Parameters

      1. Error of Flowmeter
      LLQ series gas roots flowmeter has the typical error curve and pressure loss curve of volumetric air flowmeter, 
      refer to the figure below for details:


      Measuring Range
      Flow Range Table of CX-GRFM-LLQ Series Gas Roots Flowmeter

      Nominal
      Diameter
      (mm)
      Model Starting
      Flow
      m3/h
      Flow Range
      m3/h
      Maximum
      Pressure
      Loss
      Pa
      Range
      Ratio

       
      Pressure
      Grade
      MPa
      Accuracy
      %
      Material
      50 LLQ-50A 0.05 1.00~20.00 80 20:1 1.0 1.0, 1.5 Aluminum
      LLQ-50B 0.07 1.25~25.00 80 20:1 1.0 1.0, 1.5 Aluminum
      LLQ-50C 0.07 1.33~40.00 100 30:1 1.0 1.0, 1.5 Aluminum
      LLQ-50D 0.07 1.00~60.00 140 60:1 1.0 1.0, 1.5 Aluminum
      LLQ-50E 0.07 1.21~85.00 200 70:1 1.0 1.0, 1.5 Aluminum
      80 LLQ-80A 0.07 1.43~100.00 150 70:1 1.0 1.0, 1.5 Aluminum
      LLQ-80B 0.08 1.17~140.00 220 120:1 1.0 1.0, 1.5 Aluminum
      LLQ-80C 0.15 2.86~200.00 230 70:1 1.0 1.0, 1.5 Aluminum
      80 LLQ-100A 0.11 3.13~250.00 300 80:1 1.0 1.0, 1.5 Aluminum
      LLQ-100B 0.11 2.73~300.00 350 110:1 1.0 1.0, 1.5 Aluminum
      LLQ-100C 0.11 4.09~450.00 450 110:1 1.0 1.0, 1.5 Aluminum
      LLQ-100D 0.11 5.55~500.00 550 110:1 1.0 1.0, 1.5 Aluminum
      150 LLQ-150A .0.65 8.13~650.00 450 80:1 1.0 1.0, 1.5 Aluminum
      LLQ-150B 0.76 10.00~800.00 500 80:1 1.0 1.0, 1.5 Aluminum
      LLQ-150C 0.76 12.50~1000.00 600 80:1 1.0 1.0, 1.5 Aluminum
      LLQ-150D 0.76 13.33~1200.00 700 90:1 1.0 1.0, 1.5 Aluminum
      200 LLQ-200A 1.15 30.19~1600.00 650 53:1 1.0 1.0, 1.5 Aluminum
      Model Selection, Installation & Operation Maintenance of Flowmeter
       
       
      1. Model of Product
      CX-GRFM-LLQ-□-□-□-□-□
                           ① ② ③ ④ ⑤
       
      Description
       Nominal diameter (mm) and flow range: If complete with 50 A means the caliber is 50 mm, the flow range is
       1~20 m3/h. Please refer to the model in Flow Range Table for specific completion.

       Complete I with chemical gauge head (conventional); complete II with totalizer gauge 
        head (intelligent); complete III with double gauge heads.

       Complete I0 with current output; complete N with N/A.

       Complete R4 with RS485 communication; complete R2 with RS232C

      communication; complete RM with standard MODBUS protocol; complete RH with standard HART protocol;
       complete N with N/A. 
       Complete IC with quantitation pulse output of IC card; complete N with N/A
       Complete maximum working pressure (e.g. 1.6 MPa).

      Last:CX-IGFM-XIG industrial gas flo.. Next:CX-GMFM-XZL gas mass flow meter

      Contact Us

      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

      Phone:021-57635022

      E-mail:info@gnflowmeter.com

      E-mail:sales@gninstruments.com

      關閉
    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>