      Type:Explosion-proof Thermocouple

      Illustrate:It is usually connected with display meter, recording meter and computer, etc. to directly measure temperature of liquid, vapor, gas and solid surface ranging from 0℃ to 1300℃ with explosives such as hydrocarbon on production spot.

      Explosion-proof Thermocouple

       

      Application
      It is usually connected with display meter, recording meter and computer, etc. to directly measure temperature of liquid, vapor, gas and solid surface ranging from 0℃ to 1300℃ with explosives such as hydrocarbon on production spot.

      Features
      Various explosion-proof types, good explosion-proof performance
      Spring thermal element with good shock-proof performance
      Wide measuring range
      High mechanical strength, good pressure-resistant performance

      Operation Theory
      Explosion-proof thermocouple has a junction box of enough strength with gaps inside it. All spare parts which might produce spark, electric arc, and dangerous high temperature are sealed in the junction box. When explosion within the box happens, fire and high temperature caused by explosion could be extincted and cooled with the gap. Thus, explosion separation could be realized.
       
      Main Technical Parameters
      Executive Standard
      IEC584
      GB/T16839-1997
      JB/T5518-1991
      GB3836
       
      Insulation Resistance at Normal Temperature
      The insulation resistance between electrode and protection tube of the thermocouple shall be no less than 1000MΩ m under condition that environment temperature is 20±15℃,relative humidity is more than 80%, and testing voltage is D.C.500V ±50V.
       

      Certificates List 

      Explosion-proof Class Certificate No. Certifying institution 
      d ⅡBT4 GTB96450 NEPSI
      d ⅡBT4 GTB96453 NEPSI
      d ⅡCT5 GTB98339 NEPSI
      d ⅡCT5 GTB97197 NEPSI
      iaⅡCT6 GTB99412 NEPSI

      Remarks: NEPSI National Explosion-Proof Security Inspection 
       
       
      Measuring Range & Tolerance


       

      Type Graduation Tolerance Class
      I II
      Tolerance Value Measuring Range °C Tolerance Value Measuring Range °C
      WRN K ±1.5°C -40~+375 ±2.5 °C -40~+333
      ±0.004ltl 375~1000 ±0.0075 ltl 333~1200
      WRM N ±1.5°C -40~+375 ±2.5°C -40~+333
      ±0.004 ltl 375~1000 ±0.0075 ltl 333~1200
      WRE E ±1.5°C -40~+375 ±1.5°C -40~+333
      ±0.004 ltl 375~800 ±0.004 ltl 333~900
      WRF J ±1.5°C -40~+375 ±1.5°C -40~+333
      ±0.004 ltl 375~750 ±0.004 ltl 333~750
      WRC T ±1.5°C -40~+125 ±1°C -40~+133
      ±0.004 ltl 125~350 ±0.0075 ltl 133~350

       
      Indication of Explosion-proof Function 
       

      d      Ⅱ      □     T□        
               Temperature Group: T1-T6  
        Explosion-proof Class: A, B, C
           Electric Equipment for plant 
             Explosion Separation Type 
              Intrinsic Safety Type   

       
      Electric Equipment Category
       
      I –Electric Equipment for Coal Mine Well 
      II –Electric Equipment for Plant
       
       
       
      Explosion-proof Class
      It is divided into Class A, B, and C according to maximum test safety gap in explosive gas compound.
       

      Category Class Max.Test Safety Gap
      A 0.9≤MESG
      B 0.5<MESG<0.9
      C MESG≤0.5

       
      Temperature Group
      It includes T1-T6 according to maximum surface temperature allowed of open part.

      Temperature Group Max. Surface Temperature Allowed
      T1 450
      T2 300
      T3 200
      T4 135
      T5 100
      T6 85

       
      Explosion-proof Class
      EXd II □ T □
      EXia II □T □
       
      Protection Class
      IP65
      Junction Box 
       
       
      Terminal
       
       
       
      Type Naming Method 
       

      W Temperature instrument
        R Thermocouple
          Thermal Element Material
      M NiCrSi-NiSi
      N NiCr-NiSi
      E NiCr-CuNi 
      F Fe- CuNi
      C Cu- CuNi
         
       
      Filament
      blank Simplex  
      2       2 Duplex  
       
       
      Mounting &fixing
      1 Without fixing device
      2 Threaded connector
      4 Fixed flange
      5 Elbow tube connector
      7 Straight tube connector
      8 Fixed threaded tube connector
      9 Movable threaded tube connector
        Junction box
      4 Explosion-proof Type
       
       
      Protection Tube Diameter
        0Φ16 
        Measuring End 
      G Variable cross section
      W R N 2 2 4 0 G Model example


       

      Last:thermocouple without fixing dev.. Next:Without the

      Contact Us

      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

      Phone:021-57635022

      E-mail:info@gnflowmeter.com

      E-mail:sales@gninstruments.com

      關(guān)閉
    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>