      Type:Industrial Composite PH/ORP Electrode

      Illustrate: It adopts the world-class solid dielectric and a large area of PCE liquid for junction, difficult to block and easy to maintain.

      CX-IC-1705、CX-IC-1706、CX-IC-1707 
      Industrial Composite PH/ORP Electrode
      Features
      ◆ It adopts the world-class solid dielectric and a large area of PCE liquid for junction, difficult to block and
      easy to maintain.
      ◆ Long-distance reference diffusion channel greatly extends the service life of electrodes in the harsh
      environment.
      ◆ There is no need for additional dielectric and there is a little amount of maintenance.
      ◆ High accuracy, fast response and good repeatability
       
      Model No.: CX-IC-1705
      Measuring range: 0~14PH   Applicable temperature: 0~80℃
      Accuracy: ≤ 0.02PH    Response time: ≤ l0sec
      Slope: ≥96%  Zero point potential: E0=7PH±0.3
      Internal resistance: MΩ(25℃)≤ 50MΩ
      Drift: ≤ 0.03PH/24h  no accumulation
      Installation: Rotary locking type and tail 3/4 thread (Rotate the electrode for 1/4 
      circle to insert it into or take it out of the process.)
      It is widely used for measurement of all kinds of pure water and high-purity water in 
      such places as thermal power plants (with the flow cell).
       
      Model No.: CX-IC-1706
      Measuring range: 0~14PH  Temperature range: 0-85℃
      Compressive strength: 0.6MPa  Material: PPS/PC
      Installation Size: Upper and Lower 3/4NPT Pipe Thread  Connection: Low-noise 
      cable goes out directly.
      The antimony is relatively sturdy and corrosion-resistant, which meets the 
      requirements for solid electrodes, corrosion resistance and the measurement of the 
      water body containing hydrofluoric acid, such as the wastewater treatment in 
      semiconductors and iron and steel industries. The antimony-sensitive film is used for 
      the industries corrosive to the glass. But there are also limitations. If the measured 
      ingredients are replaced by antimony or react with antimony to produce complex 
      ions, they should not be used.
      Note: Keep the antimony electrode surface cleaning; if necessary, the fine 
      Sandpaper can be used to polish the surface of antimony.
       
      Model No.: CX-IC-1707
      Measuring range: 0-2000mV  Temperature range: 0-85℃
      Compressive strength: 0.6MPa  Material: PPS/PC
      Installation Size: Upper and Lower 3/4NPT Pipe Thread  Connection: Low-noise 
      cable goes out directly.
      It is used for the oxidation reduction potential detection in medicine, chlor-alkali 
      chemical, dyes, pulp & paper-making, intermediates, chemical fertilizer, starch, 
      environmental protection and electroplating industries.
       Electrode Structure Chart                          Electrode Wiring Plug
                   

      Last:Industrial Ultra-pure Water PH .. Next:Industrial Composite Pure Water..

      Contact Us

      Office Address: Rm612-613.Jiahe Sunnyplaza.No.76.Jiuxin road.Jiuting Town,shanghai,china

      Phone:021-57632436

      E-mail:info@gnflowmeter.com