      Differential Pressure Transmitter Selection

      Email:sales01@cxflowmeter.com
      whatsapp:008618049841995
      Today a customer needs to purchase our differential pressure transmitter, he provided the following information:
       
      Range: 2000 PSI, 0-200" WC calibration, 0-400" WC
      Output 4-20MA + HART
      Power supply rating: 24VDC
      Size/connection: 1/2" FNPT with adapter
      Explosion-proof level: E EXD IIC, E EXIA
      IP identification: IP66, 67
      2-wire loop power supply
      Electrical connection: 1/2" NPTF
      Body/flange material: CU-AI/316SS
      Diaphragm/wetted parts: HASTALOY C/316SS
      Filling fluid material: Silicone
      Turndown ratio: 40 to 1
      Stability: -+0.015% URL
      Accuracy: -+0.075% URL
      Humidity: 0-95% RH -10- 60 C
      5-way SS Manifold
      Local display must be configurable in engineering units
      Mounting bracket 2 inches
      Configurable: HART
      Technician reply:
       
      1. It can meet the explosion-proof level, but the certificate cannot be provided,
       
      2. The filling medium is silicone oil,
       
      3. The range ratio is 100:1,
       
      4. Stability 0.25%,
       
      5. Accuracy 0.075%,
       
      6. Ask the customer what it means that the local display must be configurable in engineering units. The display unit of the product itself can be adjusted,
       
      7. There are three ranges. Let the customer confirm which one to choose
       
      8. The protection level is IP65

       
      There is no problem with the other parameters. After confirming the above with the customer, if the customer thinks it is okay, CX-PT-3051A-4/H-D-40Mpa
      can be used, and it can also be equipped with 316 five-group valve.
       
      If you are also looking for a suitable differential pressure transmitter pressure sensor, but don’t know how to choose, welcome to consult CIXIFM winny:
      Email:sales01@cxflowmeter.com
      whatsapp:008618049841995



       

      Last:acid centrifugal pump Next:Selection of magnetic metering ..

      Contact Us

      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

      Phone:021-57635022

      E-mail:info@gnflowmeter.com

      E-mail:sales@gninstruments.com

      關(guān)閉
    • <blockquote id="o6sq2"><tfoot id="o6sq2"></tfoot></blockquote>
      <center id="o6sq2"></center>
    • <th id="o6sq2"><nav id="o6sq2"></nav></th>
    • <ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>
        <samp id="o6sq2"></samp><ul id="o6sq2"><tbody id="o6sq2"></tbody></ul>